Double pressure gauge for Bezzera Ellisse machines, with a 70 mm outer bezel, a 63 mm body and two 1/8″ male fittings at the rear. The boiler scale runs from 0 to 2.5 bar and the pump scale from 0 to 16 bar; being a narrower band than the 3 bar scales, needle movement at working pressure can be read more precisely. Measure the bezel and the panel cut-out before ordering.

Prices and availability on request. We reply in English or Portuguese.

Specifications

Compatible withBezzera — Ellisse
Typepressure gauge double (two scale)
Bezel diameter70 mm (section outer)
Body diameter63 mm (inside cavity panel)
Boiler scale0 to 2.5 bar
Pump scale0 to 16 bar
Connectionstwo inlet thread male 1/8″ (behind gauge)

Compatible with

FAQ

Does it fit other Bezzera models?
It was designed for the Bezzera Ellisse, but it fits models using a 70 mm bezel and a 63 mm housing with a 1/8″ fitting. Confirm all three measurements before ordering, or send us a photograph of the panel and the gauge currently fitted.
Why is the 2.5 bar scale an advantage?
The band is narrower than on generic 3 bar scales, so the same working-pressure range — between 1 and 1.5 bar — covers a wider arc of the dial. In practice, a small pressure deviation is spotted sooner.
What dimensions and fittings does it have?
A 70 mm outer bezel, a 63 mm body that enters the panel cut-out, and two 1/8″ male thread inlets at the rear. The boiler scale reaches 2.5 bar and the pump scale 16 bar.
What are the signs of failure?
A needle stuck at zero or wavering constantly, which indicates a damaged Bourdon mechanism, and condensation behind the glass, a sign the seal has gone: legibility drops and internal corrosion begins.
The boiler needle reads 2 bar; is the gauge faulty?
Not necessarily — the real pressure may be high because of the pressure switch setting. Compare first against a reference gauge; if that reads differently, the fitted one is in error. Request a quote using the form on this page.